RFM SEM910DX Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Redes RFM SEM910DX. RFM SEM910DX User`s guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
SEM910 /X /D /DX
Wireless Ethernet Bridge
User’s Guide
Vista de página 0
1 2 3 4 5 6 ... 32 33

Resumo do Conteúdo

Página 1 - User’s Guide

SEM910 /X /D /DX Wireless Ethernet Bridge User’s Guide

Página 2

SEM910 The remote radio assembly has mounting holes to secure the antenna. The antenna is attached to the remote radio through the included 24-inch RF

Página 3 - Table of Contents

SEM910 Complete the assembly by placing the connector in the slot in one of the shell halves. Install the two retaining screws on both sides of the s

Página 4 - Introduction

SEM910 If a pin is accidentally installed in the wrong connector location, simply loosen the screw, remove the pin, re-insert it into the proper locat

Página 5 - Getting Started

SEM910 Configuring the SEM The network that the SEM is connected to must be compatible with 10/100BaseT products. Before connecting a default configur

Página 6 - SEM910, SEM910D

SEM910 Open IP Hunter by double-clicking on the file iphunter.exe on the SEM910 CD. The following screen will appear. Click on the Search button to

Página 7

SEM910 Double-clicking on a device with an IP address of 0.0.0.0 will bring up the following dialog box. Enter the desired IP address and the default

Página 8 - SEM910X/DX

SEM910 HTML Setup Once an address has been assigned, double-click on the IP number to launch an HTML setup session in a browser window. The login scre

Página 9

SEM910 System Settings This dialog allows the user to change the Hostname, set the Default Route, enter DNS entries or change the Outmax (upload/do

Página 10

SEM910 Bridge Settings This dialog allows the user to set the Mode, (Master or Slave), any Filtering (see the section on Filtering below) and wheth

Página 11

SEM910 Access Control Users This dialog allows the modification of logins and the ability to add new users. Note: Click on Save Settings to store th

Página 12

Important Regulatory Information Cirronet Product FCC ID: HSW-910M IC 4492A-910M Note: This unit has been tested and found to comply with t

Página 13 - Configuring the SEM

SEM910 The SEM will report back the time it took to the save the information. Reset the SEM by typing: reset<CR> The SEM can also be reset by c

Página 14

SEM910 SEM Operation Overview SEM devices are wireless Ethernet modems that perform bridging functions in point-to-point or point-to-multipoint config

Página 15

SEM910 the master automatically configures the radio in the master as a base radio. Similarly, configuring a SEM as a slave automatically configures t

Página 16 - HTML Setup

SEM910 If the application has more slave devices, or if it is desirable to increase the throughputs of the slaves at the expense of the master SEM, co

Página 17

SEM910 SEM Command Set The SEM supports a series of commands that allow for configuring the Ethernet interface as well as the radio parameters of the

Página 18

SEM910 arp Manipulates the address resolution procedure table. This command is provided primarily as a debugging tool for setting up networks. ipaddr

Página 19

SEM910 Bridge Commands Command Description help Displays help screen for command access <accesscode> Sets access code to allow slave SEM onto

Página 20

SEM910 SEM Security Commands Command Description access help console [enable|disable] ip [help add <ipaddr> delete <ipa

Página 21 - SEM Operation

SEM910 Radio Commands Command Description slave [ help disconnect <id-id-id> list] (Master only)Displays help screen for command Disconnects

Página 22

SEM910 The following commands are issued by typing radio and then the subcommand followed by the subcommand parameters if any. Command Description hel

Página 23

Table of Contents Introduction ...

Página 24 - SEM Command Set

SEM910 maxslaves Sets a limit to the number of slaves SEMS that a master SEM can have registered simultaneously. The default is 15 but the parameter

Página 25

SEM910 Specifications Model SEM910 SEM910X SEM910D SEM910DX Data Throughput 150Kbps Total over-the-air bandwidth 172.8Kbps Network Interface 10/100Bas

Página 26

SEM910 Troubleshooting Ethernet Link LED is not on. Check the power LED on the SEM. Check the Ethernet cable, making sure that it is fully connecte

Página 27

SEM910 Warranty Seller warrants solely to Buyer that the goods delivered hereunder shall be free from defects in materials and workmanship, when given

Página 28

SEM910 Introduction The SEM910 family of products from Cirronet™ Incorporated provides wireless Ethernet connectivity between networks located more th

Página 29

SEM910 Getting Started The SEM family of wireless Ethernet modems is easy to install and operate. In most instances, the only installation steps will

Página 30

SEM910 SEM910, SEM910D Figures 1, 2 & 3 show the various connectors and LEDs on the SEM910 and SEM910D. Figure 1. SEM910 Front Panel Diagram Fi

Página 31 - Specifications

SEM910 Connectors The RF connection on the SEM is the antenna on the top of the SEM910D. The antenna connector is a reverse-TNC male type connector.

Página 32 - Troubleshooting

SEM910 SEM910X/DX Figures 4, 5 & 6 show the connectors and LEDs on the SEM910X & SEM910DX radios. Figure 7 illustrates the remote radio assemb

Página 33 - Warranty

SEM910 Figure 6. SEM910DX Front Panel Diagram Figure 7. Remote Radio Assembly © 2000- 2004 Cirronet™ Inc 6 M-910-0003 Rev -

Comentários a estes Manuais

Sem comentários