RFM HN-591 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Redes RFM HN-591. RFM HN-591 User`s guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - User’s Guide

HN-591 900MHz Desktop Wireless Modem User’s Guide

Página 2

HN-591 Parameters Tab The Wizard program opens the main screen with the Parameters Tab displayed. The parameters screen of the Wizard allows the foll

Página 3 - Table of Contents

HN-591 Network Number This parameter is also known as Set Hopping Pattern. By using different network numbers or “hopping patterns”, nearby or co-loc

Página 4

HN-591 Roaming Mode This parameter allows remote radios to link to any base station or only link to specific base stations. Protocol Mode This par

Página 5 - Introduction

HN-591 Default The Default button (shown above) returns all parameters to Factory settings. Network Tab Clicking on the Network tab will bring up a

Página 6 - Antenna Connection

HN-591 Set Data Transmit Delay When used in conjunction with the minimum data length parameter, sets the amount of time from the receipt of a first b

Página 7 - Configuring the HN-591

HN-591 Set Packet Retries If ARQ Mode is set to 0, it sets the number of times the radio will attempt to send an unsuccessful transmission before di

Página 8

HN-591 Protocol Tab The Protocol tab brings up the configuration screen above. On the next page are descriptions of the commands/parameters that are

Página 9

HN-591 Set the Frequency Operating Range by clicking on the drop-down menu and making a selection. ¹ Set Radio Power Setting up by clicking on a se

Página 10

HN-591 RF Tools Clicking on the RF Tools tab brings up a screen that allows the receive signal strength to be monitored and the link quality to be ob

Página 11 - . It allows the setting

HN-591 Click on OK and the Select Connect Range screen will appear. Click on the estimated distance between radios and click OK. A bar will appear s

Página 12

Important Regulatory Information Cirronet Product FCC ID: HSW-910M IC 4492A-910M Note: This unit has been tested and found to comply with t

Página 13

HN-591 Receive Only and Bi-Directional Transmissions The Receive Only function displays the percentage success rate for receiving transmissions fro

Página 14

HN-591 The bars will change color depending on the level of the signal received. The points at which they change color have been set in the .INI file

Página 15

HN-591 Saving Configurations Configuration settings that have been applied from the Wizard can be saved for future use. The Wizard prompts to save cha

Página 16 - Protocol Tab

HN-591 Serial Commands These commands affect the serial interface between the modem and the host. The default settings are 9600 bps and protocol mode

Página 17

HN-591 Set Protocol Mode Enables the base station to operate in a multipoint network. Depending on the user application, more or less acknowledgment

Página 18

HN-591 Network Commands Network commands are used to set up a HopNet network and to set radio addressing and configuration. Command Description wb[?|0

Página 19

HN-591 Enable Global Network Mode For networks with multiple base stations, remotes are ordinarily only able to link to one base station, set by the h

Página 20

HN-591 Protocol Commands These commands can be used to tune the transceiver for optimum transmission of data across the RF link. For most application

Página 21

HN-591 Set Hop Duration Sets the length of time the transceiver spends on each frequency channel. A smaller value will allow the remote to lock on to

Página 22 - Modem Commands

HN-591 Set Data Transmit Delay When used in conjunction with the minimum data length parameter, this sets the amount of time from the receipt of a fir

Página 23 - Serial Commands

Table of Contents Introduction ... 1

Página 24

HN-591 Status Commands These commands deal with general interface aspects of the operation of the HopNet. Command Description zb[?|0|1] Banner D

Página 25 - Network Commands

HN-591 Read Factory Serial Number High, Middle and Low Bytes. These read only commands return one of the three bytes of the unique factory-set serial

Página 26

HN-591 Memory Commands The user is able to store a configuration in nonvolatile memory, which is loaded during the initialization period every time th

Página 27 - Protocol Commands

HN-591 Modem Command Summary Serial Commands sd[?|02..8f] Set Data Rate Divisor sp[?|00..14] Set Protocol Mode Network Commands wb[?|0|1] Se

Página 28

HN-591 Typical HopNet Applications Introduction The illustration below shows a complete network of multiple data sources connected to a central base.

Página 29 - 2FH which corresponds to 188

HN-591 Point-to-Point A point-to-point application as shown below provides a communication data link between two locations. HN-591 HN-591 © 2000- 2

Página 30 - Status Commands

HN-591 Troubleshooting Overview Introduction Troubleshooting the HopNet products is not difficult, but it does require a logical approach. It is best

Página 31

HN-591 Common System Problems The following table offers suggestions for resolving some common system problems that the operator may experience from t

Página 32 - Memory Commands

HN-591 Guidelines for Reducing Interference Introduction The transceivers share the same frequency spectrum with other services and other Part 15 devi

Página 33 - Modem Command Summary

HN-591 Customer Support Introduction Cirronet, Inc. products are designed for long life and trouble free operation. The following information is provi

Página 34 - Typical HopNet Applications

Recall Factory Defaults... 28 Recall Memory ...

Página 35

HN-591 Glossary of Terms Refer to the following list of terms that may be unfamiliar to you. These terms are used throughout this document. Term Defi

Página 36 - Troubleshooting

HN-591 Technical Specifications General Specification Value Frequency Band • 902 to 927MHz (USA) Number of Channels • 54 US Approvals • US FCC: Par

Página 37 - Common System Problems

HN-591 Mechanical Specification Value Case • Metal Size • 5 in. x 3.5 in. x 1 in. • 127mm x 89mm x 25mm Weight • 0.5 lb • 227 g Data Connector •

Página 38

HN-591 Appendix A HNWizard INIT.INI File One of the files unpacked with the program is the INIT.INI file. It contains the entries below and an explana

Página 39 - Customer Support

HN-591 HNWizard’s WinCom Window Normally, the WinCom Window is not displayed and no tab will appear to the right of the RF Tools tab. To display the

Página 40 - Glossary of Terms

HN-591 NOTE: If the banner does not display, check the Banner Display Disable command (zb0) which may have been enabled. The COM port and baud rat

Página 41 - Technical Specifications

HN-591 If an invalid command or value is entered, the radio will respond with “Error” as shown above Until the command to save the parameters (m>)

Página 42 - Environmental

HN-591 The Clear Screen button deletes all the text in the display window. The Clear CTS and Clear DCD buttons reset the respective changes counters

Página 43 - Appendix A

HN-591 Restart The Restart button on the Wizard causes the program to start the radio search and parameter load process again without shutting the pro

Página 44 - HNWizard’s WinCom Window

HN-591 Warranty Seller warrants solely to Buyer that the goods delivered hereunder shall be free from defects in materials and workmanship, when given

Página 45

HN-591 Introduction The HN-591 provides reliable wireless connectivity for either point-to-point or point-to-multipoint applications. The HN-591 is bu

Página 46

HN-591 Data Transmission The HN-591 can be used as either a base or as a remote. The HN-591 can usually transmit to 1000 feet indoors and in excess of

Página 47

HN-591 Configuring the HN-591 Overview Introduction You can configure the HopNet network using the HNWizard software provided or a PC running a termin

Página 48

HN-591 HopNet Configuration Wizard (HNWizard) Open the Wizard by double-clicking on the icon on the desktop. When the Wizard boots up, it will automat

Página 49 - Warranty

HN-591 When a parameter value is changed from the value currently in the HopNet radio, the parameter label and value will turn red and the Apply Setti

Comentários a estes Manuais